ERDEM YAPI

New Garnet 70 & New Garnet 70

Yetkili Üretici Bayi

New Term New Garnet & New Garnet in the 70 series

Today’s urban culture and building technology are shaped and changing in brand new dimensions. Cities are filled with differentiating silhouettes of this change. Our new living spaces; It emphasizes the principles of aesthetics, insulation, comfort and energy efficiency. By closely following this change, we meet the needs of differentiated construction technologies with a new series. Commenting the 70 serial standards with a different aesthetic and insulation approach, the new Garnet and 3 session continue to be the new choice of modern structures.

ERDEM YAPI

Window Pattern Options
Gold Oak
Ancient Walnut
White
Juniper
Anthracite
Eloksal Gray
Budaklı Maun
Foolish Oak
Walnut
Night Blue
Hazelnut
Smoked
Smooth Anthracite
Grey
Silver Grey
Chestnut
Dark Green
Rustic Oak
Satin Gray
Cream
Cedar
Black

Over Standard Solutions in 70 Series

Designed to carry the insulation and aesthetics of window standards to a new dimension, the new Garnet and the new Garnet Strong series increase the comfort of your living spaces with excellent heat and sound insulation. The new Garnet and 3 gasket Garnet Strong with all profiles with a width of 70 mm and 5 chambers is the choice of a new generation architecture, which is in search of a different aesthetics. Yeni Garnet and Yeni Garnet strongly meet the expectations of new trends in decoration with 22 different color options and start a new era in modern buildings by providing superior heat and sound insulation in 70 series. By offering windows of different colors inside and outside, it develops alternatives that are compatible with your decoration and wall color as well as the outer surface of your structures.

Experience, Technology and Design United in Selenit 75

Wind load strength
• When designing Selenit, the power criterion of the PVC profiles is observed at the highest rates of the motto of inertia of the support sheets to be used within the system and the “wind load strength ıyla related to it.
• offers new solutions used safely to close high -storey structures and wide openings.
• The Griyag profiles of the system easily provide the ideal strength values when it is desired to close wide openings in terms of architectural design.
• The high strength values of the Selenit system have successfully passed the 3,000 PA (245 km/h) security test and entered the C3 class in the wind load classification.

System

• All main profiles provide maximum insulation values in 70 series with its new Garnet 3 gasket design in the Garnet system with a width of 70 mm and a class B thickness.
• The system has 4 different types of lath types that increase the inner surface width and offer 4 different decorative bar alternatives.
• Thanks to the detail and auxiliary profiles designed in accordance with the main profiles, it can easily solve all architectural details.
• Thanks to the lava profiles of the system, glass can be applied up to 40 mm.
• New Garnet and Yeni Garnet Strong series offer options that will meet and add value to your home with 22 different laminated color alternatives.

Wind Load Strength

• The Garnet system was designed according to 1800 PA safety test and 600 PA (110 km/h) water sealing strength test and successfully passed through these tests.
• The new Garnet Strong series with 3 gaskets offers excellent solutions to provide strength in structures with high wind load.
• When developing the Garnet system, the maximum wind load values that structures may be exposed to are taken into consideration, and their positions in the structure of the support sheets and their positions in the profile are designed to get maximum efficiency.
• The system easily ensures that the wide openings in the structures and the necessary strength values easily provide solutions to meet the architectural expectations.

Water and Air Sealing

• While designing new Garnet and New Garnet Strong series, it is aimed to keep the heat transmission coefficient value, which is the most important point for energy conservation in PVC window systems, at the lowest value.
• The system’s profile widths, chambers numbers and chamber widths have been developed to keep heat and sound insulation at the highest levels.
• The best insulation values that can be captured in a 70 PVC window system with the 3rd medium gasket system have been reached.
• All profiles of the Garnet system have a 5 -chamber structure and because the width of the chamber is large, the heat transmission coefficient values are low.
• In accordance with TS EN ISO 10077-2 Standard, 1,23 m x 1,43 m with window system is reached with 0.7 W/m2k, UW: 1,05 W/M2K and UF: 1.2 W/m2K values .

Thermal Insulation

• The new Garnet Strong series is designed with 3 gaskets to keep air and water permeability at the lowest levels.
• Preventing air passage from the outdoor to the internal environment required for energy conservation is achieved with the middle gasket in addition to the standard internal and external control.
• The Garnet system provides high resistance to rain even in high wind loads, thanks to its water drainage angle and sets developed to ensure that water evacuation is faster and more comfortable.
• 600 PA (110 km/h) There was no water leakage to the internal environment in tests under wind load.

Sound Insulation

• One of the most important quality criteria of window systems is sound insulation. The airport, railway or large highway structures near the 70 dB loud levels of new Garnet and new Garnet Strong systems, a child can easily sleep, the sound level of 30 dB falls to six values.
• With the new Garnet and Yeni Garnet Strong series, sound insulation can be provided up to 40 dB. Thus, it is possible to create a sound environment at high quality life level even in the most noisy environments.

Call Now !